The DT9208A digital multimeter is a versatile helper for servicing, workshops and household electrical work. It offers DC/AC voltage and current measurement, resistance, capacitance, frequency and temperature measurement, a clear LCD display, a protective rubber case and measuring accessories included in the package.
Wide range of measurement options
The multimeter supports measurement of direct and alternating voltage and current, resistance, capacitor capacitance, frequency and temperature. It is suitable for diagnosing electrical and electronic circuits.
Clear controls and LCD display
The large LCD display makes it easy to read the measured values. The central rotary switch allows intuitive selection of the measuring function and range.
Protective case and practical accessories
The rubber protective case increases the device's resistance during everyday use. The package includes measuring leads, a probe and AAA batteries.
The DT9208A digital multimeter enables quick and accurate verification of electrical values during repairs, diagnostics and routine electronics maintenance. The rotary switch makes it easy to select the required function, while the measured values can be conveniently read on the large LCD display.
The multimeter measures direct and alternating voltage and current, resistance, capacitor capacitance, frequency and temperature. It also includes practical functions for diode testing, continuity testing and hFE transistor testing. The protective rubber case helps protect the device from mechanical damage.
Package contents:
- DT9208A digital multimeter,
- set of measuring leads,
- test probe,
- 2× AAA batteries,
- original packaging.
Specifications
- Model
- DT9208A
- Direct voltage (DCV)
- 0.2 mV to 1000 V; ranges 200 mV / 2 V / 20 V / 200 V / 1000 V
- DCV accuracy
- up to 200 V ±(0.5% + 1); 1000 V ±(0.8% + 2)
- Alternating voltage (ACV)
- 0.2 mV to 750 V; ranges 200 mV / 2 V / 20 V / 200 V / 750 V
- ACV accuracy
- 200 mV ±(1.2% + 3); 2–200 V ±(0.5% + 1); 750 V ±(1.2% + 5)
- Direct current (DCA)
- 10 µA to 20 A; ranges 2 mA / 20 mA / 200 mA / 20 A
- DCA accuracy
- 2 mA ±(0.8% + 1); 20 mA ±(1% + 3); 200 mA ±(1.2% + 1); 20 A ±(2% + 5)
- Alternating current (ACA)
- 10 µA to 20 A; ranges 20 mA / 200 mA / 20 A
- ACA accuracy
- 20 mA ±(1% + 3); 200 mA ±(1.8% + 3); 20 A ±(2% + 5)
- Resistance
- 0.2 Ω to 200 MΩ; ranges 200 Ω / 2 kΩ / 20 kΩ / 200 kΩ / 2 MΩ / 20 MΩ / 200 MΩ
- Resistance measurement accuracy
- 200 Ω ±(0.8% + 3); 2 kΩ to 2 MΩ ±(0.8% + 1); 20 MΩ ±(1% + 2); 200 MΩ ±(5% + 10)
- Capacitance
- 1 pF to 200 µF; ranges 2 nF / 20 nF / 200 nF / 2 µF / 200 µF
- Capacitance measurement accuracy
- ±(4% + 3)
- Temperature
- -40 to 1000 °C
- Temperature measurement accuracy
- -40 to 400 °C ±0.75% (±3); 400 to 1000 °C ±1.5% (±5)
- Frequency
- up to 200 kHz, ±1.5% (±10)
- Transistor test
- Yes, hFE
- Diode test
- Yes
- Continuity test
- Yes
- Automatic shutdown
- Yes
- Display
- LCD, display range 1–999
- Display dimensions
- 33 × 63 mm
- Power supply
- 2× AAA batteries
- Weight
- 300 g
- Dimensions
- 91 × 189 × 32 mm
- Safety standard
- IEC-1010, overvoltage category CAT II / CAT III, pollution degree 2
- Certification
- CE